Harvard Anderson Group WB57 Total Water |
Connector: | J56LMB |
---|---|
Local Name: | J56LMB |
Location: | LMB: Lamp Module B |
Type: | B-18 |
Description: | Lamp Module B |
Cabled To: | J56WDP2. and J56RFB. |
Pin | Signal | Link-To | Cable-To |
---|---|---|---|
A | BModP @ 0xDAE | J56WDP2.11 | |
B | HtBSt @ 0xDE8 | J56WDP2.6 | |
C | HtBSt_Rtn | J56WDP2.7 | |
D | +28v_LMB | J56WDP2.18 | |
E | 28v_Rtn | J29LMB.2 | J56WDP2.20 |
F | BVisV_HI | J56WDP2.2 | |
G | B_LMT_HI | J56WDP2.10 | |
H | BVisV_LO | J56WDP2.3 | |
J | +15v | J56WDP2.12 | |
K | -15v | J56WDP2.14 | |
L | Ana_Gnd | J56LMB.S | J56WDP2.16 |
M | |||
N | |||
P | |||
R | |||
S | Ana_Gnd | J29LMB.5 | J56WDP2.17 |
T | |||
U |
[LMB] [Components] [Master] [Signals] [Check]
Web listings compiled using Nets
software on Wed Apr 11 15:07:30 2001
Copyright 2001 by the President and Fellows of Harvard College