ClONO2 Experiment
Component Main DP MDP
Idx64-2
Connector MDP:J34 SE-80
Cable P34

Connected via cable P34 to IDX2, connector J1

  Pin    Signal                               Link To          Follow
  1      GND(MDP)                             Fanout           ==>
  2      STEP_AF1                             J120.52          ==>
  3      VDD                                  Fanout           ==>
  4      DIR_AF1                              J120.53          ==>
  5      ENABLE_AF1                           J120.54          ==>
  6      VDD                                  Fanout           ==>
  7      INLIMIT_AF1                          J120.55          ==>
  8      GND(MDP)                             Fanout           ==>
  9      OUTLIMIT_AF1                         J120.56          ==>
  10     GND(MDP)                             Fanout           ==>
  11     ZEROREF_AF1                          J120.57          ==>
  12     KILL_A_AF1                           J120.58          ==>
  13     KILL_B_AF1                           J120.59          ==>
  14     GND(MDP)                             Fanout           ==>
  15     STEP_AF2                             J120.60          ==>
  16     VDD                                  Fanout           ==>
  17     DIR_AF2                              J120.61          ==>
  18     ENABLE_AF2                           J120.62          ==>
  19     VDD                                  Fanout           ==>
  20     INLIMIT_AF2                          J120.63          ==>
  21     GND(MDP)                             Fanout           ==>
  22     OUTLIMIT_AF2                         J120.64          ==>
  23     GND(MDP)                             Fanout           ==>
  24     ZEROREF_AF2                          J120.65          ==>
  25     KILL_A_AF2                           J120.66          ==>
  26     KILL_B_AF2                           J120.67          ==>
  27     GND(MDP)                             Fanout           ==>
  28     STEP_E                               J120.68          ==>
  29     VDD                                  Fanout           ==>
  30     DIR_E                                J120.69          ==>
  31     ENABLE_E                             J120.70          ==>
  32     VDD                                  Fanout           ==>
  33     INLIMIT_E                            J120.71          ==>
  34     GND(MDP)                             Fanout           ==>
  35     OUTLIMIT_E                           J120.72          ==>
  36     GND(MDP)                             Fanout           ==>
  37     ZEROREF_E                            J120.73          ==>
  38     KILL_A_E                             J120.74          ==>
  39     KILL_B_E                             J120.75          ==>
  40     GND(MDP)                             Fanout           ==>
  41     GND(MDP)                             Fanout           ==>
  42     STEP_B                               J121.13          ==>
  43     VDD                                  Fanout           ==>
  44     DIR_B                                J121.14          ==>
  45     ENABLE_B                             J121.15          ==>
  46     VDD                                  Fanout           ==>
  47     INLIMIT_B                            J121.16          ==>
  48     GND(MDP)                             Fanout           ==>
  49     OUTLIMIT_B                           J121.17          ==>
  50     GND(MDP)                             Fanout           ==>
  51     ZEROREF_B                            J121.18          ==>
  52     KILL_A_B                             J121.19          ==>
  53     KILL_B_B                             J121.20          ==>
  54     GND(MDP)                             Fanout           ==>
  55     STEP_11                              E.218            ==>
  56     VDD                                  Fanout           ==>
  57     DIR_11                               E.219            ==>
  58     ENABLE_11                            E.220            ==>
  59     VDD                                  Fanout           ==>
  60     INLIMIT_11                           E.221            ==>
  61     GND(MDP)                             Fanout           ==>
  62     OUTLIMIT_11                          E.222            ==>
  63     GND(MDP)                             Fanout           ==>
  64     ZEROREF_11                           E.223            ==>
  65     KILL_A_11                            E.224            ==>
  66     KILL_B_11                            E.225            ==>
  67     GND(MDP)                             Fanout           ==>
  68     STEP_12                              E.226            ==>
  69     VDD                                  Fanout           ==>
  70     DIR_12                               E.227            ==>
  71     ENABLE_12                            E.228            ==>
  72     VDD                                  Fanout           ==>
  73     INLIMIT_12                           E.229            ==>
  74     GND(MDP)                             Fanout           ==>
  75     OUTLIMIT_12                          E.230            ==>
  76     GND(MDP)                             Fanout           ==>
  77     ZEROREF_12                           E.231            ==>
  78     KILL_A_12                            E.232            ==>
  79     KILL_B_12                            E.233            ==>
  80     GND(MDP)                             Fanout           ==>
[MDP] [Systems] [Cables] [Signals]

Connector pin assignments by Terry Allen.
Web listings compiled by Norton T. Allen May 31, 1996.

(c)1996 Harvard University Atmospheric Research Project