ClONO2 Experiment
Component Main DP MDP
Idx64-1
Connector MDP:J33 SE-80
Cable P33

Connected via cable P33 to IDX1, connector J1

  Pin    Signal                               Link To          Follow
  1      GND(MDP)                             Fanout           ==>
  2      STEP_SV1(MDP)                        J40.65           ==>
  3      VDD                                  Fanout           ==>
  4      DIR_SV1(MDP)                         J40.66           ==>
  5      ENABLE_SV1(MDP)                      J40.67           ==>
  6      VDD                                  Fanout           ==>
  7      INLIMIT_SV1(MDP)                     J40.70           ==>
  8      GND(MDP)                             Fanout           ==>
  9      OUTLIMIT_SV1(MDP)                    J40.71           ==>
  10     GND(MDP)                             Fanout           ==>
  11     ZEROREF_SV1                          E.31             ==>
  12     KILL_A_SV1(MDP)                      J40.69           ==>
  13     KILL_B_SV1(MDP)                      J40.68           ==>
  14     GND(MDP)                             Fanout           ==>
  15     STEP_GV1(MDP)                        J40.73           ==>
  16     VDD                                  Fanout           ==>
  17     DIR_GV1(MDP)                         J40.74           ==>
  18     ENABLE_GV1(MDP)                      J40.75           ==>
  19     VDD                                  Fanout           ==>
  20     INLIMIT_GV1(MDP)                     J40.78           ==>
  21     GND(MDP)                             Fanout           ==>
  22     OUTLIMIT_GV1(MDP)                    J40.79           ==>
  23     GND(MDP)                             Fanout           ==>
  24     ZEROREF_GV1                          E.32             ==>
  25     KILL_A_GV1(MDP)                      J40.77           ==>
  26     KILL_B_GV1(MDP)                      J40.76           ==>
  27     GND(MDP)                             Fanout           ==>
  28     STEP_SV2                             J38.65           ==>
  29     VDD                                  Fanout           ==>
  30     DIR_SV2                              J38.66           ==>
  31     ENABLE_SV2                           J38.67           ==>
  32     VDD                                  Fanout           ==>
  33     INLIMIT_SV2                          J38.70           ==>
  34     GND(MDP)                             Fanout           ==>
  35     OUTLIMIT_SV2                         J38.71           ==>
  36     GND(MDP)                             Fanout           ==>
  37     ZEROREF_SV2                          E.29             ==>
  38     KILL_A_SV2                           J38.69           ==>
  39     KILL_B_SV2                           J38.68           ==>
  40     GND(MDP)                             Fanout           ==>
  41     GND(MDP)                             Fanout           ==>
  42     STEP_GV2                             J38.73           ==>
  43     VDD                                  Fanout           ==>
  44     DIR_GV2                              J38.74           ==>
  45     ENABLE_GV2                           J38.75           ==>
  46     VDD                                  Fanout           ==>
  47     INLIMIT_GV2                          J38.78           ==>
  48     GND(MDP)                             Fanout           ==>
  49     OUTLIMIT_GV2                         J38.79           ==>
  50     GND(MDP)                             Fanout           ==>
  51     ZEROREF_GV2                          E.30             ==>
  52     KILL_A_GV2                           J38.77           ==>
  53     KILL_B_GV2                           J38.76           ==>
  54     GND(MDP)                             Fanout           ==>
  55     STEP_PV                              J100.2           ==>
  56     VDD                                  Fanout           ==>
  57     DIR_PV                               J100.3           ==>
  58     ENABLE_PV                            J100.4           ==>
  59     VDD                                  Fanout           ==>
  60     INLIMIT_PV                           J100.7           ==>
  61     GND(MDP)                             Fanout           ==>
  62     OUTLIMIT_PV                          J100.8           ==>
  63     GND(MDP)                             Fanout           ==>
  64     ZEROREF_PV                           E.209            ==>
  65     KILL_A_PV                            J100.6           ==>
  66     KILL_B_PV                            J100.5           ==>
  67     GND(MDP)                             Fanout           ==>
  68     STEP_5                               E.210            ==>
  69     VDD                                  Fanout           ==>
  70     DIR_5                                E.211            ==>
  71     ENABLE_5                             E.212            ==>
  72     VDD                                  Fanout           ==>
  73     INLIMIT_5                            E.213            ==>
  74     GND(MDP)                             Fanout           ==>
  75     OUTLIMIT_5                           E.214            ==>
  76     GND(MDP)                             Fanout           ==>
  77     ZEROREF_5                            E.215            ==>
  78     KILL_A_5                             E.216            ==>
  79     KILL_B_5                             E.217            ==>
  80     GND(MDP)                             Fanout           ==>
[MDP] [Systems] [Cables] [Signals]

Connector pin assignments by Terry Allen.
Web listings compiled by Norton T. Allen May 31, 1996.

(c)1996 Harvard University Atmospheric Research Project