ClONO2 Experiment
Component Main DP MDP
D/A-4
Connector MDP:J14 E-20
Cable P14

Connected via cable P14 to DA4, connector J17

  Pin    Signal                               Link To          Follow
  1      SPARE_J14_1                          Fanout           ==>
  2      NO_Flow_Control                      J80.29           ==>
  3      ANAGND                               Fanout           ==>
  4      NO2_Flow_Control                     J81.21           ==>
  5      ANAGND                               Fanout           ==>
  6      ClONO2_Flow_Control                  J80.47           ==>
  7      ANAGND                               Fanout           ==>
  8      O3_Flow_Control                      J80.18           ==>
  9      ANAGND                               Fanout           ==>
  10     Aux_Htr_Setpoint                     J17.17           ==>
  11     AUX_HTR_SETPOINT_RTN                 J17.18           ==>
  12     Laser_Diode_1_I_Setpoint             J17.3            ==>
  13     ANAGND                               Fanout           ==>
  14     Laser_Diode_2_I_Setpoint             J17.9            ==>
  15     ANAGND                               Fanout           ==>
  16     Spare_Setpoint_1                     E.140            ==>
  17     SPARE_SETPOINT_RTN_1                 E.139            ==>
  18     SPARE_J14_1                          Fanout           ==>
  19     SPARE_J14_1                          Fanout           ==>
  20     SPARE_J14_1                          Fanout           ==>
[MDP] [Systems] [Cables] [Signals]

Connector pin assignments by Terry Allen.
Web listings compiled by Norton T. Allen May 31, 1996.

(c)1996 Harvard University Atmospheric Research Project