ClONO2 Experiment
Component Indexer Board IDX2
Indexer Interface
Connector IDX2:J1 SE-80
Cable P34

Connected via cable P34 to MDP, connector J34

  Pin    Signal                               Link To          Follow
  1      GND(MDP)                             Fanout           ==>
  2      STEP_AF1                             U6.18            ==>
  3      VDD                                  Fanout           ==>
  4      DIR_AF1                              U6.16            ==>
  5      ENABLE_AF1                           U6.14            ==>
  6      VDD                                  Fanout           ==>
  7      INLIMIT_AF1                          C45.1            ==>
                                              U6.8                            
                                              Z6.8                            
  8      GND(MDP)                             Fanout           ==>
  9      OUTLIMIT_AF1                         C44.1            ==>
                                              U6.11                           
                                              Z6.9                            
  10     GND(MDP)                             Fanout           ==>
  11     ZEROREF_AF1                          C43.1            ==>
                                              U6.13                           
                                              Z6.7                            
  12     KILL_A_AF1                           C42.1            ==>
                                              U6.15                           
                                              Z6.5                            
  13     KILL_B_AF1                           C41.1            ==>
                                              U6.17                           
                                              Z6.3                            
  14     GND(MDP)                             Fanout           ==>
  15     STEP_AF2                             U5.18            ==>
  16     VDD                                  Fanout           ==>
  17     DIR_AF2                              U5.16            ==>
  18     ENABLE_AF2                           U5.14            ==>
  19     VDD                                  Fanout           ==>
  20     INLIMIT_AF2                          C40.1            ==>
                                              U5.8                            
                                              Z5.8                            
  21     GND(MDP)                             Fanout           ==>
  22     OUTLIMIT_AF2                         C39.1            ==>
                                              U5.11                           
                                              Z5.9                            
  23     GND(MDP)                             Fanout           ==>
  24     ZEROREF_AF2                          C38.1            ==>
                                              U5.13                           
                                              Z5.7                            
  25     KILL_A_AF2                           C37.1            ==>
                                              U5.15                           
                                              Z5.5                            
  26     KILL_B_AF2                           C36.1            ==>
                                              U5.17                           
                                              Z5.3                            
  27     GND(MDP)                             Fanout           ==>
  28     STEP_E                               U4.18            ==>
  29     VDD                                  Fanout           ==>
  30     DIR_E                                U4.16            ==>
  31     ENABLE_E                             U4.14            ==>
  32     VDD                                  Fanout           ==>
  33     INLIMIT_E                            C35.1            ==>
                                              U4.8                            
                                              Z4.8                            
  34     GND(MDP)                             Fanout           ==>
  35     OUTLIMIT_E                           C34.1            ==>
                                              U4.11                           
                                              Z4.9                            
  36     GND(MDP)                             Fanout           ==>
  37     ZEROREF_E                            C33.1            ==>
                                              U4.13                           
                                              Z4.7                            
  38     KILL_A_E                             C32.1            ==>
                                              U4.15                           
                                              Z4.5                            
  39     KILL_B_E                             C31.1            ==>
                                              U4.17                           
                                              Z4.3                            
  40     GND(MDP)                             Fanout           ==>
  41     GND(MDP)                             Fanout           ==>
  42     STEP_B                               U3.18            ==>
  43     VDD                                  Fanout           ==>
  44     DIR_B                                U3.16            ==>
  45     ENABLE_B                             U3.14            ==>
  46     VDD                                  Fanout           ==>
  47     INLIMIT_B                            C30.1            ==>
                                              U3.8                            
                                              Z3.8                            
  48     GND(MDP)                             Fanout           ==>
  49     OUTLIMIT_B                           C29.1            ==>
                                              U3.11                           
                                              Z3.9                            
  50     GND(MDP)                             Fanout           ==>
  51     ZEROREF_B                            C28.1            ==>
                                              U3.13                           
                                              Z3.7                            
  52     KILL_A_B                             C27.1            ==>
                                              U3.15                           
                                              Z3.5                            
  53     KILL_B_B                             C26.1            ==>
                                              U3.17                           
                                              Z3.3                            
  54     GND(MDP)                             Fanout           ==>
  55     STEP_11                              U2.18            ==>
  56     VDD                                  Fanout           ==>
  57     DIR_11                               U2.16            ==>
  58     ENABLE_11                            U2.14            ==>
  59     VDD                                  Fanout           ==>
  60     INLIMIT_11                           C25.1            ==>
                                              U2.8                            
                                              Z2.8                            
  61     GND(MDP)                             Fanout           ==>
  62     OUTLIMIT_11                          C24.1            ==>
                                              U2.11                           
                                              Z2.9                            
  63     GND(MDP)                             Fanout           ==>
  64     ZEROREF_11                           C23.1            ==>
                                              U2.13                           
                                              Z2.7                            
  65     KILL_A_11                            C22.1            ==>
                                              U2.15                           
                                              Z2.5                            
  66     KILL_B_11                            C21.1            ==>
                                              U2.17                           
                                              Z2.3                            
  67     GND(MDP)                             Fanout           ==>
  68     STEP_12                              U1.18            ==>
  69     VDD                                  Fanout           ==>
  70     DIR_12                               U1.16            ==>
  71     ENABLE_12                            U1.14            ==>
  72     VDD                                  Fanout           ==>
  73     INLIMIT_12                           C20.1            ==>
                                              U1.8                            
                                              Z1.8                            
  74     GND(MDP)                             Fanout           ==>
  75     OUTLIMIT_12                          C19.1            ==>
                                              U1.11                           
                                              Z1.9                            
  76     GND(MDP)                             Fanout           ==>
  77     ZEROREF_12                           C18.1            ==>
                                              U1.13                           
                                              Z1.7                            
  78     KILL_A_12                            C17.1            ==>
                                              U1.15                           
                                              Z1.5                            
  79     KILL_B_12                            C16.1            ==>
                                              U1.17                           
                                              Z1.3                            
  80     GND(MDP)                             Fanout           ==>
[IDX2] [Systems] [Cables] [Signals]

Connector pin assignments by Terry Allen.
Web listings compiled by Norton T. Allen May 31, 1996.

(c)1996 Harvard University Atmospheric Research Project