ClONO2 Experiment
Component Indexer Board IDX1
Indexer Interface
Connector IDX1:J1 SE-80
Cable P33

Connected via cable P33 to MDP, connector J33

  Pin    Signal                               Link To          Follow
  1      GND(MDP)                             Fanout           ==>
  2      STEP_SV1(MDP)                        U6.18            ==>
  3      VDD                                  Fanout           ==>
  4      DIR_SV1(MDP)                         U6.16            ==>
  5      ENABLE_SV1(MDP)                      U6.14            ==>
  6      VDD                                  Fanout           ==>
  7      INLIMIT_SV1(MDP)                     C45.1            ==>
                                              U6.8                            
                                              Z6.8                            
  8      GND(MDP)                             Fanout           ==>
  9      OUTLIMIT_SV1(MDP)                    C44.1            ==>
                                              U6.11                           
                                              Z6.9                            
  10     GND(MDP)                             Fanout           ==>
  11     ZEROREF_SV1                          C43.1            ==>
                                              U6.13                           
                                              Z6.7                            
  12     KILL_A_SV1(MDP)                      C42.1            ==>
                                              U6.15                           
                                              Z6.5                            
  13     KILL_B_SV1(MDP)                      C41.1            ==>
                                              U6.17                           
                                              Z6.3                            
  14     GND(MDP)                             Fanout           ==>
  15     STEP_GV1(MDP)                        U5.18            ==>
  16     VDD                                  Fanout           ==>
  17     DIR_GV1(MDP)                         U5.16            ==>
  18     ENABLE_GV1(MDP)                      U5.14            ==>
  19     VDD                                  Fanout           ==>
  20     INLIMIT_GV1(MDP)                     C40.1            ==>
                                              U5.8                            
                                              Z5.8                            
  21     GND(MDP)                             Fanout           ==>
  22     OUTLIMIT_GV1(MDP)                    C39.1            ==>
                                              U5.11                           
                                              Z5.9                            
  23     GND(MDP)                             Fanout           ==>
  24     ZEROREF_GV1                          C38.1            ==>
                                              U5.13                           
                                              Z5.7                            
  25     KILL_A_GV1(MDP)                      C37.1            ==>
                                              U5.15                           
                                              Z5.5                            
  26     KILL_B_GV1(MDP)                      C36.1            ==>
                                              U5.17                           
                                              Z5.3                            
  27     GND(MDP)                             Fanout           ==>
  28     STEP_SV2                             U4.18            ==>
  29     VDD                                  Fanout           ==>
  30     DIR_SV2                              U4.16            ==>
  31     ENABLE_SV2                           U4.14            ==>
  32     VDD                                  Fanout           ==>
  33     INLIMIT_SV2                          C35.1            ==>
                                              U4.8                            
                                              Z4.8                            
  34     GND(MDP)                             Fanout           ==>
  35     OUTLIMIT_SV2                         C34.1            ==>
                                              U4.11                           
                                              Z4.9                            
  36     GND(MDP)                             Fanout           ==>
  37     ZEROREF_SV2                          C33.1            ==>
                                              U4.13                           
                                              Z4.7                            
  38     KILL_A_SV2                           C32.1            ==>
                                              U4.15                           
                                              Z4.5                            
  39     KILL_B_SV2                           C31.1            ==>
                                              U4.17                           
                                              Z4.3                            
  40     GND(MDP)                             Fanout           ==>
  41     GND(MDP)                             Fanout           ==>
  42     STEP_GV2                             U3.18            ==>
  43     VDD                                  Fanout           ==>
  44     DIR_GV2                              U3.16            ==>
  45     ENABLE_GV2                           U3.14            ==>
  46     VDD                                  Fanout           ==>
  47     INLIMIT_GV2                          C30.1            ==>
                                              U3.8                            
                                              Z3.8                            
  48     GND(MDP)                             Fanout           ==>
  49     OUTLIMIT_GV2                         C29.1            ==>
                                              U3.11                           
                                              Z3.9                            
  50     GND(MDP)                             Fanout           ==>
  51     ZEROREF_GV2                          C28.1            ==>
                                              U3.13                           
                                              Z3.7                            
  52     KILL_A_GV2                           C27.1            ==>
                                              U3.15                           
                                              Z3.5                            
  53     KILL_B_GV2                           C26.1            ==>
                                              U3.17                           
                                              Z3.3                            
  54     GND(MDP)                             Fanout           ==>
  55     STEP_PV                              U2.18            ==>
  56     VDD                                  Fanout           ==>
  57     DIR_PV                               U2.16            ==>
  58     ENABLE_PV                            U2.14            ==>
  59     VDD                                  Fanout           ==>
  60     INLIMIT_PV                           C25.1            ==>
                                              U2.8                            
                                              Z2.8                            
  61     GND(MDP)                             Fanout           ==>
  62     OUTLIMIT_PV                          C24.1            ==>
                                              U2.11                           
                                              Z2.9                            
  63     GND(MDP)                             Fanout           ==>
  64     ZEROREF_PV                           C23.1            ==>
                                              U2.13                           
                                              Z2.7                            
  65     KILL_A_PV                            C22.1            ==>
                                              U2.15                           
                                              Z2.5                            
  66     KILL_B_PV                            C21.1            ==>
                                              U2.17                           
                                              Z2.3                            
  67     GND(MDP)                             Fanout           ==>
  68     STEP_5                               U1.18            ==>
  69     VDD                                  Fanout           ==>
  70     DIR_5                                U1.16            ==>
  71     ENABLE_5                             U1.14            ==>
  72     VDD                                  Fanout           ==>
  73     INLIMIT_5                            C20.1            ==>
                                              U1.8                            
                                              Z1.8                            
  74     GND(MDP)                             Fanout           ==>
  75     OUTLIMIT_5                           C19.1            ==>
                                              U1.11                           
                                              Z1.9                            
  76     GND(MDP)                             Fanout           ==>
  77     ZEROREF_5                            C18.1            ==>
                                              U1.13                           
                                              Z1.7                            
  78     KILL_A_5                             C17.1            ==>
                                              U1.15                           
                                              Z1.5                            
  79     KILL_B_5                             C16.1            ==>
                                              U1.17                           
                                              Z1.3                            
  80     GND(MDP)                             Fanout           ==>
[IDX1] [Systems] [Cables] [Signals]

Connector pin assignments by Terry Allen.
Web listings compiled by Norton T. Allen May 31, 1996.